WEFLO Pressure Relief Valve FL x Gr FIG.F1349
Specifications:
- Relief Valve: Limits inlet pressure by relieving excess pressure.
- Pressure sustaining: Prevents pipe line pressure from rising toa maximum valve.
- Operates over a Wide Flow Range.
- Inlet Pressure Adjustment Range:65~300psi.
- Quick opening and adjustable closing speed.
- Flanged to EN 1092-3 PN16,ANSI Class150/300(Other available on request)
- Grooved Ends to AWWA C606 Standard.
- Rated Working Pressure 300 psi.
- UL1478 Listed and FM 1361Approved,
Description
Reviews (0)
Be the first to review “WEFLO Pressure Relief Valve FL x Gr FIG.F1349” Cancel reply
Shipping & Delivery
Related products
WEFLO NRS Resilient Seated Gate Valve Flanged Ends & Grooved Ends FIG.F0299
Specifications:
Ductile-Iron Wedge, EPDM Encapsulated.
Triple O-Ring Stem Seal.
Face to Face Dimensions to ANSI/ASME B16.10EN558,Series 3.
Flange Drilling toANSIB16.1,Class 125,ASME B16.42, Class 150Flat Faced Standard, Raised Face Upon Request. Grooved Ends to AWWA C606 Standard.
UL/ULC Listed/FM Approved @ 300 psi rating
3C Certified.
WEFLO C515 NRS Resilient Seated Gate Valve 14“-24” FIG.F1211-300
Specifications :
Multiple End TypesF1211-300:Flange by FlangeF0213-300:Flange by MJF0233-300:MJ by MJ
Meet or exceed the requirements of AWWA C515 Standard.
Full Waterway.
Triple O-Ring Stem Seal.
Ductile-Iron Wedge, EPDM Encapsulated.
Operated with handwheel or operating nut.
Flanged to ASME B16.1 Class 125.
Other Flange Types available upon request. Mechanical Joint Outlets comply withANSIAWWAC153/A21.53Rated Working Pressure: 300 psi.
UL/ULC Listed and FM Approved.
WEFLO Angle Fire Pump Relief Valve FL x FL Ends F1329
Specifications:
Flanged to EN 1092-2 PN16,ANSI Class125/150/250.
(Other available on request)
Opens quickly: maintains pressure within close limits.
Wide range adjustable:65psi-300psi(4.5 bar -21 bar).
Pilot operated main valve.
Reduced cavitation design.
Simple field adjustable pressure setting, requiring no special tools or system down time.
Closes gradually for surge-free operation.
UL 1478 Listed and FM 1361 Approved.
*Limits maximum pump discharge pressure.
*Factory tested & preset to requirements.
Applicable forwater, foam.
300psi(21bar)high Working Pressure
600psi(42bar)Hydrostatic Test
Fusion Bonded Epoxy Coated Interior and Exterior toAWWA C550 Standard.
WEFLO Air Release Valve FIG.9701
WEFLO Sing Orifice Air Relief Valve FIG.9105
Specifications:
Provides the functions of both Air Release and Air / Vacuum Valves.
Exhausts large quantities of air at system start-up.
Provides protection from pipeline collapse due to vacuum.
Incorporates both features within one valve, More compact and economical.
Flange and drilling to A N S I B16. 1 Class125(Other flange types available upon request) e Rated Working Pressure 300 psi.
UL Listed.
WEFLO Angle Fire Pump Relief Valve FL x Gr Ends FIG.F1339
Specifications :
- Flanged to EN 1092-3 PN16. ANSI Class 150/300. (Other available on request)
- Grooved Ends to AWWA C606 Standard.
- Opens quickly: maintains pressure within close limits.
- Wide range adjustable : 65psi-300psi (4.5 bar-21 bar).
- Limits maximum pump discharge pressure.
- Factory tested & preset to requirements.
- Applicable for water. sea water & foam.
- 300psi (21bar) high Working Pressure 600psi (42bar) Hydrostatic Test
- Pilot operated main valve.
- Reduced cavitation design.
- Simple field adjustable pressure setting, requiring no special tools or system down time.
- Closes gradually for surge-free operation.
- UL 1478 Listed and FM 1361 Approved.
WEFLO Pressure Relief Valve Gr x Gr Ends FIG.F1319
Specifications
Relief Valve: Limits inlet pressure by relieving excess pressure.
Pressure sustaining: Prevents pipe line pressure from rising to a maximum valve.
Operates over a Wide Flow Range.
*Inlet Pressure Adjustment Range: 65-300psi.
Quick opening and adjustable closing speed.
*Grooved Ends to AWWA C606 Standard.
Rated Working Pressure 300 psi.
UL 1478 Listed and FM 1361 Approved.
Reviews