WEFLO NRS Resilient Seated Gate Valve With Extension Spindles Fig.GD1 – GD2
Specification :
- GD1:150≤H1≤1000, GD2:H1>1000.
- The distance from the center line of the valve to the ground shall be provided by the customer.
- When providing the data, please be sure that the error must not exceed +20mm.
- Equipped with T-wrench:10 sets of same size gate valves are equipped with one T-wrench.
- Customers need to purchase this wrench if they need more.
- This direct buried gate valve is equipped with BS 5163 resilient seated gate valve or FM /ULNRS resilient seated gate valve.
- H-dimension shall be supplied on order.
- Valve operated by T-key.
Description
Reviews (0)
Be the first to review “WEFLO NRS Resilient Seated Gate Valve With Extension Spindles Fig.GD1 – GD2” Cancel reply
Shipping & Delivery
Related products
WEFLO C515 OS& amp Y Resilient Seated Gate Valve 14“-24” FIG.F1111-300
Specifications :
Multiple End Types
F1111-300:Flange by FlangeF0113-300:Flange by MJF0133-300:MJby MJ
Meet or exceed the requirements ofAWWAC515 Standard.
Full Waterway.
Adjustable Packing.
Ductile-Iron Wedge, EPDM Encapsulated.
Flanged to ASME B16.1 Class 125.OtherFlangeTypes available upon request. Mechanical Joint Outlets comply with ANSI/AWWAC153/A21.53Rated Working Pressure: 300 psi. UL/ULC Listed and FM Approved,
WEFLO Pressure Relief Valve Gr x Gr FIG.F1349
Specifications:
- Relief Valve: Limits inlet pressure by relieving excess pressure.
- Pressure sustaining: Prevents pipe line pressure from rising toa maximum valve.
- Operates over a Wide Flow Range.
- Inlet Pressure Adjustment Range:65~300psi.
- Quick opening and adjustable closing speed.
- Grooved Ends to AWWA C606 Standard.
- Rated Working Pressure 300 psi.
- UL1478 Listed and FM 1361 Approved.
WEFLO Angle Fire Pump Relief Valve FL x FL Ends F1329
Specifications:
Flanged to EN 1092-2 PN16,ANSI Class125/150/250.
(Other available on request)
Opens quickly: maintains pressure within close limits.
Wide range adjustable:65psi-300psi(4.5 bar -21 bar).
Pilot operated main valve.
Reduced cavitation design.
Simple field adjustable pressure setting, requiring no special tools or system down time.
Closes gradually for surge-free operation.
UL 1478 Listed and FM 1361 Approved.
*Limits maximum pump discharge pressure.
*Factory tested & preset to requirements.
Applicable forwater, foam.
300psi(21bar)high Working Pressure
600psi(42bar)Hydrostatic Test
Fusion Bonded Epoxy Coated Interior and Exterior toAWWA C550 Standard.
WEFLO Swing Check Valve, Flanged Ends FIG.F1322
Specifications
Meet or exceed the requirements of AWWA C508 Standard.
Full Waterway.
Disc is fully encapsulated with EPDM rubber.
Superior design featuring exceptionally low pressure losses at high flow rates.
Disassembly of the valve can be performed without removing the valve from the pipe system by unscrewing the bonnet bolts. Face to face dimensions according to ASME B16.10.Flanged to ASME B16.1 Class 125,EN 1092-2 PN16.Other flange types are available on request. Rated Working Pressure: 350 psi. UL/ULC Listed and FM Approved.
ANSI/NSF61&372 Certified.
WEFLO NRS Resilient Seated Gate Valve Flanged Ends & Grooved Ends FIG.F0299
Specifications:
Ductile-Iron Wedge, EPDM Encapsulated.
Triple O-Ring Stem Seal.
Face to Face Dimensions to ANSI/ASME B16.10EN558,Series 3.
Flange Drilling toANSIB16.1,Class 125,ASME B16.42, Class 150Flat Faced Standard, Raised Face Upon Request. Grooved Ends to AWWA C606 Standard.
UL/ULC Listed/FM Approved @ 300 psi rating
3C Certified.
WEFLO Double Orifice Air Relief Valve FIG.9106
Specifications
Dual air release vents the accumulated small volumes of air during normal system operation.
Allows inflow of large volumes of air during draining of the pipeline.
Allows venting of large volumes of air during filling of the pipeline.
Provides protection from pipeline collapse due to vacuum.
Flange and drilling to ANSI B16.1 Class125.(Other flange types available upon request)
Rated Working Pressure 300 psi.
.UL Listed.
WEFLO Pressure Relief Valve FL x FL Ends-FIG.F1319
Specifications:
Relief Valve: Limits inlet pressure by relieving excess pressure.
Pressure sustaining: Prevents pipe line pressure from rising toa maximum valve.
*Operates over a Wide Flow Range.
*Inlet Pressure Adjustment Range: 65-300psi.
Quick opening and adjustable closing speed.
Flanged to EN 1092-2 PN16,ANSIClass125/150/250.
(Other available on request)Rated Working Pressure 300 psi.
UL 1478 Listed and FM 1361 Approved.
WEFLO Sing Orifice Air Relief Valve FIG.9105
Specifications:
Provides the functions of both Air Release and Air / Vacuum Valves.
Exhausts large quantities of air at system start-up.
Provides protection from pipeline collapse due to vacuum.
Incorporates both features within one valve, More compact and economical.
Flange and drilling to A N S I B16. 1 Class125(Other flange types available upon request) e Rated Working Pressure 300 psi.
UL Listed.
Reviews
There are no reviews yet.