Specifications:
Flanged to EN 1092-2 PN16,ANSIClass125/150/250
(Other available on request)
Grooved Ends to AWWA C606 Standard.
Opens quickly; maintains pressure within close limits.
Wide range adjustable: 65psi-300psi(4.5 bar-21 bar).
Pilot operated main valve.
Reduced cavitation design. Simple field adjustable pressure setting, requiring no special tools or system down time. Closes gradually for surge-free operation.
UL1478 Listed and FM 1361 Approved.
Limits maximum pump discharge pressure.
Factory tested & preset to requirements.
Applicable forwater. foam.
300psi(21bar)high Working Pressure
600psi(42bar)Hydrostatic Test
Fusion Bonded Epoxy Coated Interior and Exterior toAWWAC550 Standard.
Description
Reviews (0)
Be the first to review “WEFLO Angle Fire Pump Relief Valve FL x Gr Ends F1329” Cancel reply
Shipping & Delivery
Related products
WEFLO Angle Fire Pump Relief Valve Gr x Gr Ends FIG.F1339
Specifications :
- Grooved Ends to AWWA C606 Standard.
- Opens quickly: maintains pressure within close limits.
- Wide range adjustable: 65psi-300psi(4.5 bar-21 bar).
- Pilot operated main valve.
- Reduced cavitation design.
- Limits maximum pump discharge pressure.
- Factory tested & preset to requirements.
- Applicable for water, sea water & foam.
- 300psi(21bar)high Working Pressure 600psi (42bar) Hydrostatic Test
- Simple field adjustable pressure setting, requiring no special tools or system down time.
- Closes gradually for surge-free operation.
- UL 1478 Listed and FM 1361 Approved.
WEFLO Pressure Reducing Valve FIG.F1321-300
Specifications
Multiple End Types for Main Valve:
Flange by Flange, Flange by Groove, Groove by Groove. Pressure Relief Valve:
Limits pipe line pressure by release excess pressure.
Pressure sustaining: Prevents pipe line pressure from rising to a maximum value.
Operates over a wide flow range.*Inlet pressure adjustment range: 65~180psi.Can be maintained without removal from the pipe line.
Flanged to EN1092-2 PN10/PN16,ANSI B16.1 Class125(Other available on request)
Grooved ends to AWWA C606 Standard.
Rated Working Pressure: 300 psi.
Adjustment Range of Set Pressure: 65 to 180 psi.Fusion Bonded Epoxy Coated Interior and Exterior to AWWAC550 Standard.FM 1361 Approved.CNBOP Certified.
WEFLO Swing Check Valve, Flanged Ends FIG.F1322
Specifications
Meet or exceed the requirements of AWWA C508 Standard.
Full Waterway.
Disc is fully encapsulated with EPDM rubber.
Superior design featuring exceptionally low pressure losses at high flow rates.
Disassembly of the valve can be performed without removing the valve from the pipe system by unscrewing the bonnet bolts. Face to face dimensions according to ASME B16.10.Flanged to ASME B16.1 Class 125,EN 1092-2 PN16.Other flange types are available on request. Rated Working Pressure: 350 psi. UL/ULC Listed and FM Approved.
ANSI/NSF61&372 Certified.
WEFLO Pressure Reducing Valve FLxFL Ends FIG.F1318
Specifications :
Reducing Valve: Reduces a higher inlet pressure to a lower out.
let pressure.
Constant Outlet Pressure over Wide Flow Range.
Pilot-operated main valve not subject to pressure fall off..
Outlet Pressure is adjustable with single screw.
Adjustable Opening/Response Speed.
Stabilized regulation at near-zero flow.
Flanged Ends to EN1092-2PN16,ANSI Class125/150/250.
(Other available on request)
UL1739 listed.
3C Certified.
Enamel Paint or Fusion Bonded Epoxy Coated Interior and Exterior.
WEFLO Angle Fire Pump Relief Valve FL x Gr Ends FIG.F1339
Specifications :
- Flanged to EN 1092-3 PN16. ANSI Class 150/300. (Other available on request)
- Grooved Ends to AWWA C606 Standard.
- Opens quickly: maintains pressure within close limits.
- Wide range adjustable : 65psi-300psi (4.5 bar-21 bar).
- Limits maximum pump discharge pressure.
- Factory tested & preset to requirements.
- Applicable for water. sea water & foam.
- 300psi (21bar) high Working Pressure 600psi (42bar) Hydrostatic Test
- Pilot operated main valve.
- Reduced cavitation design.
- Simple field adjustable pressure setting, requiring no special tools or system down time.
- Closes gradually for surge-free operation.
- UL 1478 Listed and FM 1361 Approved.
WEFLO Double Orifice Air Relief Valve FIG.9106
Specifications
Dual air release vents the accumulated small volumes of air during normal system operation.
Allows inflow of large volumes of air during draining of the pipeline.
Allows venting of large volumes of air during filling of the pipeline.
Provides protection from pipeline collapse due to vacuum.
Flange and drilling to ANSI B16.1 Class125.(Other flange types available upon request)
Rated Working Pressure 300 psi.
.UL Listed.
WEFLO Pressure Relief Valve FL x FL Ends-FIG.F1319
Specifications:
Relief Valve: Limits inlet pressure by relieving excess pressure.
Pressure sustaining: Prevents pipe line pressure from rising toa maximum valve.
*Operates over a Wide Flow Range.
*Inlet Pressure Adjustment Range: 65-300psi.
Quick opening and adjustable closing speed.
Flanged to EN 1092-2 PN16,ANSIClass125/150/250.
(Other available on request)Rated Working Pressure 300 psi.
UL 1478 Listed and FM 1361 Approved.
WEFLO Wafer Butterfly Valve Gear Operated F0811-300 CNPP
Specifications:
Meet or exceed the requirements of EN 593 and MSS SP-67 Standard.
Single Piece Through Shaft.
Splined Drive.
e Outdoor and Indoor rated.
Vulcanized Seat Design for Bubble-Tight Shutoff.
Flag Type Position indicator.
e Built-in Supervisory Switch.
Face to Face Dimension complies with ASME B16.10 Narrow and EN558 Series 20.
Connected Flange complies with ASME B16.5 Class 150 andEN1092 PN10/16.(Other Flange Types available upon request)®CNPP Certified.
Rated Working Pressure 300 psi.
Reviews