WEFLO Y-Type Strainer, Flanged Ends, FIG.F0511-175
Specification :
- Meet or exceed the requirements of UL 321 Standard.
- NPT or BSPT blowoff outlet on cover (blowoff outlets are furnished with plugs).
- Recessed seat in body assure accurate screen alignment
- Round holes with 60 degrees staggered.
- Excellent flow characteristics and low pressure losses at high flow rates.
- Connection Ends: ASME B16.1 Class 125 0r EN1092-2 PN10/16(Other Flange Types Available Upon Request)
- Rated Working Pressure 175 psi.
- UL321/ULC Listed.
WEFLO Waste Cone FIG.8103
Specifications:
- Available for Onshore and Offshore Applications.
- Manufactured in Accordance with NFPA20 Requirements.
- Designed for use with UL/FM Approved Fire Pump Pressure Relief Valves.
- Flanges to A N S I Class 150/300, Other available on request.
- Ductile lron-ASTMA536-65.
- (2)2"316 SS Sight Glasses per Waste Cone.
- Single Body Casting(No Welding).
WEFLO Platform Fire Hydrant U246C
Specifications :
Meet or Exceed the Requirements of UL 246C Standard.
NFPA 1963 Standard Nozzle Threads.
Bronze Body and Hose Nozzle.
0-ring Sealed Stem Nut and Hose Nozzle.
Excellent Flow Characteristics.
Multiple Nozzle Configurations.
Monitor Style available.
UL246C Listed, FM Approved.
250 psi Maximum Working Pressure.
WEFLO H-Strainer Fig.7120
Specifications :
- Large Flow Area, Low Pressure Drop.
- Service without removal from line.
- Can be installed in any position, spec installation with cover up is recommended.
- Flanged and Drilling comply with EN1092-2 PN16. Other flange types are available upon request.
- Rated Working Pressure 200 psi/16 bar.
WEFLO Explosion-Proof Vane-Type Waterflow Detector FIG.F6001EX
Specifications :
- Designed and approved to operate in hazardous locations.
- Two synchronized switches are enclosed outside of explosion environment.
- Terminals are easy to read and wire.
- Built-In mechanical time delay feature; minimizing the risk of false alarms due to pressure surges or air trapped in the system.
- Offers excellent performance during riser vibrations caused by large in-rushes of water.
- Designed and built for accuracy and repeatability.
- Hazardous Atmosphere Classification: Class I: Div. 1. Groups C, D T6; Class I: Div.2,Groups C,D T6; Class II: Div.1,Groups E,FG T6; Class II: Div.2,Groups F GT6: Class III. DNV 22 ATEX 17663X; IECEx DNV 22.0041X; Ex db lB T6 Gb; Ex tb llC T8O'c Db Ip66
- Maximum pressure:
- Flow sensitivity range
- Contact rating
- Maximum Surge: 18FPS (5.5m/s)
- Entry Size: 1/2"NPT threaded conduit connections
- NEMA 4/ P66 Rated enclosure rating
- Ambient Temperature: 0'C to 49C