WEFLO Adjustable Vertical Indicator Post FIG.F0800-IP
Specifications :
- Meet or Exceed the Requirements of NFPA 24 Standard.
- Indicates the State of the Valve OPEN or SHUT Position.
- Target Nut to allow 13 to 45 Turns.
- “L” Shaped Wrench Handle fitted with a Secure Padlock(provided by user).
- Protected Windows.
- Telescoping Operating Rod.
- Easily Adjustable indicator OPEN and SHUT Targets.
- UL/ULC 789 Listed and FM1110 Approved.
- CNBOP Certified.
Description
Reviews (0)
Be the first to review “WEFLO Adjustable Vertical Indicator Post FIG.F0800-IP” Cancel reply
Shipping & Delivery
Related products
WEFLO Explosion-Proof Pressure Switch FIG.WPSEX
- Features : Maximum Pressure: 300psi Pressure Range: WPS10EX: 4-20 psi. WPS40EX:10-200 psi.
- Factory Setting : WPS10EX: 4-8 psi.WPS40EX: operates in increasing pressure at 130 psi and on decreasing pressure 110 psi.
- Approximate Differential: WPS10EX: 3 psi throughout range. WPS40EX: 3 psi @ 10 psi & 9 psi @ 200 psi.
- Contact Rating: Two sets of SPDT: 10A @ 125/250VAC,2.5A @ 30VDC.
- Entry Size:1/2"NPT threaded conduit connections NEMA 4/P66 Rated enclosure rating
- Ambient Temperature:-40'C to 60C
- Hazardous Atmosphere Classification: DNV 22 ATEX 17667X;IECEx DNV 22.0042X: Ex db. IIB T6 Gb: IP66
WEFLO Vane-Type Waterflow Detector, CPVC & Bronze Adapter- FIG.F6001U
Features:
Equipped with tamper resistant screws to prevent unauthorized entry. The F6001U with CPVC adapter fits 1",1%",1%", and 2" CPVC tees The F6001U with bronze adapter fits 1", 1¼", 1%", and 2" brass and copper threaded tees, in addition to 1" and 1%" CPVC tees. Clearly marked plastic paddles are included to fit the different Installation configurations. Two synchronized switches are enclosed in a durable terminal block. Terminals are easy to read and wire. Built-In mechanical time delay feature; minimizing the risk of false alarms due to pressure surges or air trapped in the system. Offers excellent performance during riser vibrations caused by Large in-rushes of water.
Designed and built for accuracy and repeatability.
Rated Working Pressure: 175 psi.
Flow Sensitivity Range for Signal:15-37.8 L/min(4-10GPM)Contact Ratings:8Aat125/250VAC,3Aat 24VDC,2.5Aat 30VDCMaximum Surge:18FPS(5.5m/s)
UL/ULC Listed, FM Approved.
WEFLO Vane-Type Waterflow Detector GIF.F6001S
Features :
- Equipped with tamper resistant screws to prevent unauthorized entry.
- The F6001S fits 1", 1%",1%", and 2" brass and copper threaded tees, in addition to 1 "and 1½" CPVC tees.
- Clearly marked plastic paddles are included to fit the different installation configurations.
- One switch is enclosed in the detector.
- Terminals are easy to read and wire.
- Designed and built for accuracy and repeatability.
- Rated Working Pressure: 300 psi.
- Flow Sensitivity Range for Signal: 15-37.8 L/min (4-10GPM)
- Contact Ratings: 8Aat125/250VAC, 3Aat 24VDC.
- Maximum Surge: 18 FPS (5.5m/s)
- UL/ULC Listed
- EAC and CE Certified.
WEFLO Y-Type Strainer, Flanged Ends, FIG.F0511-175
Specification :
- Meet or exceed the requirements of UL 321 Standard.
- NPT or BSPT blowoff outlet on cover (blowoff outlets are furnished with plugs).
- Recessed seat in body assure accurate screen alignment
- Round holes with 60 degrees staggered.
- Excellent flow characteristics and low pressure losses at high flow rates.
- Connection Ends: ASME B16.1 Class 125 0r EN1092-2 PN10/16(Other Flange Types Available Upon Request)
- Rated Working Pressure 175 psi.
- UL321/ULC Listed.
WEFLO Pressure Switch FIG.WPS
Features
Maximum Adjustment Pressure Range:WPS10-1/WPS10-2:4-20 psi.
WPS40-1/WPS40-2:10-100 psi.
WPS120-1/WPS120-2:10-200psi.
Factory Setting:
WPS10-1.WPS10-2: 4-8 psi.
WPS40-1:operates at decreasing pressure at 30 psi.
WPS40-2: operates at increasing pressure at 50 psi and decreasing pressure 30 psi.
WPS120-1:operates at decreasing pressure at 110 psi.
WPS120-2: operates at increasing pressure at 130 psi and decreasing pressure 110 psi
Approximate Differential:
WPS10-1/WPS10-2:3 psi throughout range.WPS40-1/WPS40-2:3 psi@ 10 psi& 6psi @ 100 psi.
WPS120-1/WPS120-2:3 psi@ 10 psi& 9 psi @ 200 psi.
Contact Rating:10A@1251250VAC,2.5A@ 30VDCIP 66.
UL/ULC Listed, FM Approved, CE, EAC, VdS, LPCB, 3C certified.
WEFLO Water Motor and Gong, FIG.WMA-16
Operation :
When a Deluge Valve is activated, water flows through the valve's trim, discharges to a strainer and into the water motor inlet, From the inlet, the water flows through a nozzle which directs the stream to the impeller. The stream turns the Impeller and drive shaft, causing the striker arm to rotate, thus producing a continuous alarm. The water is discharged thro-ugh a 1"(25mm) drain outlet at the bottom of the impeller ho-using. The discharged water must be piped through the wall to a suitable open drain.
WEFLO Backflow Prevention Devices DCDA – RPZD – RPAD
WEFLO Backflow Prevention Devices SCV – SCDA – DCV
Description :
A single check valve is designed for use in “low hazard" conditions in services to prevent backflow caused by back-siphonage or back-pressure.
It is intended for use under continuous pressure conditions.
The check is designed to maintain a minimum of 1 psi across the check valve during normal operation.
Multiple Ends Types: Flange by Flange, Flange by Groove, Groove by Groove.
Reviews
There are no reviews yet.